Cleaning the interior of the PHS device
- Start working only with the vacuum cleaner switched off.
- Open the door of the Sifting module and tapping the flexible tube of the sieve so that the powder from the walls falls on the Vibrating Sieve.
- Operate only when the power is off! Also, switch on the E-STOP button on the Control Panel to cut off power from the internal components of the machine.
- Remove both grids from the Chambers. Pull out first the grid of the Powder Chamber and then, by lifting in the dedicated place, the grid from the Fine Dust Chamber.
- Using an Allen key, unscrew the Service access to Powder feeding screw panel. The panel holds 4 screws.
- Remove the Antistatic hose from the connector for the Antistatic hose in PHS.
- Connect a PVC brush to the pulled end of the Antistatic hose.
- Turn on the vacuum cleaner and clean the interior of the device. When vacuuming, pay attention to the electrical installation and grounding. Treat the contents of the vacuum cleaner as waste for disposal.
- When you have finished vacuuming, turn off the vacuum cleaner and remove the PVC brush from the Antistatic hose.
- Connect the Antistatic hose back to the connector for the Antistatic hose in the PHS.
- Mount the Service access to Powder feeding screw panel back in place with screws.
- Reconnect the power supply to the PHS.