Cleaning the powder feeding screw
- Start working only with the vacuum cleaner switched off.
- Open the door of the Sifting module and tapping the flexible tube of the sieve so that the powder from the walls falls on the Vibrating Sieve.
- Operate only when the power is off! Also, switch on the E-STOP button on the Control Panel to cut off power from the internal components of the machine.
- Remove both grids from the Chambers. Pull out first the grid of the Powder Chamber and then, by lifting in the dedicated place, the grid from the Fine Dust Chamber.
- Using an Allen key 5 mm, unscrew the four screws of the Powder Feeding Screw guard in the Powder Chamber and put it aside.
- Use an Allen key to unscrew the one screw of the Powder Feeding Screw guard in the Fine Dust Chamber and put it aside.
- Remove the Antistatic hose from the connector for the Antistatic hose in PHS.
- Connect a PVC brush to the pulled end of the Antistatic hose.
- Check that the grounding of your ATEX Vacuum Cleaner is properly installed.
- Turn on the vacuum cleaner and clean the Powder Feeding Screw and both chambers inside. Treat the contents of the vacuum cleaner as waste for disposal.
- After the work is finished, install the Powder Feeding guards back in the Chambers.
- Re-install both grids on the Chambers.
- Connect the Antistatic hose back to the connector for the Antistatic hose in the PHS.
- Reconnect the power supply to the PHS.